New MEP-002A from DRMO
- This topic has 1 reply, 2 voices, and was last updated 9 years, 2 months ago by .
Viewing 1 reply thread
Viewing 1 reply thread
- You must be logged in to reply to this topic.
Battle-Tested Diesel Generators and Parts › Forums › Military Generator Troubleshooting › New MEP-002A from DRMO
Good Evening everyone,
I just purchased a MEP-002A from DRMO is Portsmouth, VA. What all should I do to it before starting it to see what kind of running condition it’s in. Thanks for your help! I love GMG, great parts and info! Will definitely be a source for parts!
Clean out and blow out with compressed air the entire fuel line and system. Clean tank. Bleed all fuel lines. Install all new filters. Fresh oil. Check glow plugs. Clean out critters. Then gently start to see if unit will turn over. Before any of this, you could remove starter and make sure the flywheel turns and the engine doesn’t need to be unstuck.
Make sure to clean out the screens in the bottom of the 3 electric fuel pumps as well. Make sure the injector pump and injectors are secure and not loose.