MEP807A Manuals

MEP-807A Specifications

Identification Data
Description100 kW TQG, 50/60 Hz, DED, Skid Mtd
ModelMEP-807A
NSN6115-01-296-1463
LING17596
SSNM54400
Trailer Mounted Conf.PU-807A, Figure A-31
Physical Characteristics
Dimensions LWH (in)106 x 40 x 65 (Cube: 160 ft3)
Wet Weight (lbs)6100
EngineCaterpillar – Model: 3126B 4 cyl Turbo Diesel, 282 hp @ 1800 RPM, 24 VDC starter, liquid cooled, electronic governor, EPA certified
InstrumentationDigital Display
FuelsDiesel DL-1, DL-2; Jet Fuel JP-8.
Fuel CapacityFuel tank: 66 gallons
Performance Characteristics
Power Rating60 Hz: 100 kW, 0.8 pf @ 4000 ft/95°F, 50 Hz: 83.3 kW, 0.8 pf @ 4000 ft/95°F
Environmental Capability-25°F to 120°F, rain, humidity, altitude, sand/ dust, transportation, cold storage: – 60°F, salt spray, fungus, 15° incline.
Protective DevicesOver-speed, High temp, Low oil pressure, Low fuel, Under-voltage, Over-voltage, Short circuit, Overload, Reverse power, Diagnostics
Fuel Consumption.7.8 gph @ rated load
Human FactorsMIL-STD-1474.
Noise70/68 dBA @ 7 meters (23 ft).
Reliability (MTBOMF)1250 hr
Maintenance Ratio0.026 max
Electrical Characteristics
Connection120/208V, 3ph, 4 wire240/416V, 3ph, 4 wireFreq adj range
Volt adj range (50 Hz)190 – 213 V380 – 426 V48 – 52 Hz
Volt adj range (60 Hz)197 – 240 V395 – 480 V58 – 62 Hz
ElectricalDrip proof generator enclosure, fungus & moisture treated, solid state voltage regulator, solderless connectors, Synchronous. brushless generator
Electrical Performance
Electric Power QualityAC VoltageFrequency
Regulation3%3%
Modulation1%
Short term steady st stability (30 sec)2% bandwidth2% bandwidth
Long term steady state stability (4 hr)4% bandwidth3% bandwidth
Application/rejection of rated load, recovery time20% dip/30%rise,3 sec4% under/over,4 sec
Motor load40% dip, 5 sec to 95% init volt
Max waveform deviation factor5%
Individual waveform harmonic2%
EMIMeets MIL-STD-461
EMPHAEMP IAW MIL-STD-2169
Optional Equipment
DescriptionNSNWeight (lbs)Effect on Dimensions (in)
Winterization kitTBDTBDNone (internal)
Technical Manuals
DescriptionARMYAir ForceMarine Corps
OperatorsTM 9-6115-729-1035 C2-3-519-1TM07464C-10/1
Unit, DS, GSTM 9-6115-729-24& P35 C2-3-519-2TM07464C-24/2
Engine Maintenance
Engine Parts
Lube order
Warranty

4 thoughts on “MEP807A Manuals

  1. NERONDOMINIQUE says:

    Has anyone been able to install an auto start circuit on the mep-807A generator? need some guidance on where to start.

  2. Josue Perez says:

    I need the nsn part for the battery connection that connects both of the batteries together. I cant find it anywhere

Leave a Reply