MEP807A Manuals
MEP-807A Specifications
| Identification Data | |||
| Description | 100 kW TQG, 50/60 Hz, DED, Skid Mtd | ||
| Model | MEP-807A | ||
| NSN | 6115-01-296-1463 | ||
| LIN | G17596 | ||
| SSN | M54400 | ||
| Trailer Mounted Conf. | PU-807A, Figure A-31 | ||
| Physical Characteristics | |||
| Dimensions LWH (in) | 106 x 40 x 65 (Cube: 160 ft3) | ||
| Wet Weight (lbs) | 6100 | ||
| Engine | Caterpillar – Model: 3126B 4 cyl Turbo Diesel, 282 hp @ 1800 RPM, 24 VDC starter, liquid cooled, electronic governor, EPA certified | ||
| Instrumentation | Digital Display | ||
| Fuels | Diesel DL-1, DL-2; Jet Fuel JP-8. | ||
| Fuel Capacity | Fuel tank: 66 gallons | ||
| Performance Characteristics | |||
| Power Rating | 60 Hz: 100 kW, 0.8 pf @ 4000 ft/95°F, 50 Hz: 83.3 kW, 0.8 pf @ 4000 ft/95°F | ||
| Environmental Capability | -25°F to 120°F, rain, humidity, altitude, sand/ dust, transportation, cold storage: – 60°F, salt spray, fungus, 15° incline. | ||
| Protective Devices | Over-speed, High temp, Low oil pressure, Low fuel, Under-voltage, Over-voltage, Short circuit, Overload, Reverse power, Diagnostics | ||
| Fuel Consumption. | 7.8 gph @ rated load | ||
| Human Factors | MIL-STD-1474. | ||
| Noise | 70/68 dBA @ 7 meters (23 ft). | ||
| Reliability (MTBOMF) | 1250 hr | ||
| Maintenance Ratio | 0.026 max | ||
| Electrical Characteristics | |||
| Connection | 120/208V, 3ph, 4 wire | 240/416V, 3ph, 4 wire | Freq adj range |
| Volt adj range (50 Hz) | 190 – 213 V | 380 – 426 V | 48 – 52 Hz |
| Volt adj range (60 Hz) | 197 – 240 V | 395 – 480 V | 58 – 62 Hz |
| Electrical | Drip proof generator enclosure, fungus & moisture treated, solid state voltage regulator, solderless connectors, Synchronous. brushless generator | ||
| Electrical Performance | |||
| Electric Power Quality | AC Voltage | Frequency | |
| Regulation | 3% | 3% | |
| Modulation | 1% | ||
| Short term steady st stability (30 sec) | 2% bandwidth | 2% bandwidth | |
| Long term steady state stability (4 hr) | 4% bandwidth | 3% bandwidth | |
| Application/rejection of rated load, recovery time | 20% dip/30%rise,3 sec | 4% under/over,4 sec | |
| Motor load | 40% dip, 5 sec to 95% init volt | ||
| Max waveform deviation factor | 5% | ||
| Individual waveform harmonic | 2% | ||
| EMI | Meets MIL-STD-461 | ||
| EMP | HAEMP IAW MIL-STD-2169 | ||
| Optional Equipment | |||
| Description | NSN | Weight (lbs) | Effect on Dimensions (in) |
| Winterization kit | TBD | TBD | None (internal) |
| Technical Manuals | |||
| Description | ARMY | Air Force | Marine Corps |
| Operators | TM 9-6115-729-10 | 35 C2-3-519-1 | TM07464C-10/1 |
| Unit, DS, GS | TM 9-6115-729-24& P | 35 C2-3-519-2 | TM07464C-24/2 |
| Engine Maintenance | |||
| Engine Parts | |||
| Lube order | |||
| Warranty |
4 thoughts on “MEP807A Manuals”
Leave a Reply
You must be logged in to post a comment.

GMG does sell a MEP807A remote auto start kit here.
Has anyone been able to install an auto start circuit on the mep-807A generator? need some guidance on where to start.
Look in any of the military parts manuals (e.g. MEP003A). They all use the same connector.
I need the nsn part for the battery connection that connects both of the batteries together. I cant find it anywhere