i have a mep 816a 208v 400hz over voltage /cannot turn voltage down
- This topic has 0 replies, 1 voice, and was last updated 2 years ago by .
Viewing 0 reply threads
Viewing 0 reply threads
- You must be logged in to reply to this topic.
Battle-Tested Diesel Generators and Parts › Forums › Military Generator Troubleshooting › i have a mep 816a 208v 400hz over voltage /cannot turn voltage down
I replaced the broken 20k ohm pot for voltage adjustment. this corrected the problem temporally. The unit was on a job would not produce voltage .I found the regulator fuse blown , replaced it , now I have 300+ volts cant turn it down voltage pot tests in correct limits .I suspect the voltage regulator kit needs to be replaced ?